Shield EX 3.0-S Behind-the-Panel CO Detector – Altus/Illyrian Compatible – w/ iOS App w/Serial Output
$495.00
Shield EX 3.0-S Behind-the-Panel CO Detector – Altus/Illyrian Compatible – w/ iOS App w/Serial Output
This has Serial Output using RS-232.
Experimental Aircraft Only: The Aithre Shield EX 3.0-S is the first behind-the-panel device that puts carbon monoxide readings, pilot SPO2 from your Aithre Illyrian, and portable oxygen bottle PSI from your Aithre Altus Meso directly on EFIS using RS-232 output, as opposed to the voltage outputs of the sibling Shield EX 3.0.
The EX 3.0-S works out-of-the-box with the current version of Advanced Flight Systems Avionics firmware. Check with your avionics manufacturer to verify support of the Aithre RS-232 protocol, which is published on our website on the Instructions & Resources page. Otherwise, see the sibling Shield EX 3.0 with its standard voltage outputs that are compatible with Garmin, Dynon, and other avionics manufacturers.
Features simple wiring installation, a small lightweight footprint, iOS integration, and 10 years without recalibration for the CO ppm.
- ALTUS MESO COMPATIBLE: Wirelessly retrieves oxygen bottle PSI data from the Aithre Altus Meso to allow portable oxygen pressure to be provided to your avionics along with carbon monoxide data.
- ILLYRIAN COMPATIBLE: Wirelessly retrieves pilot blood oxygen levels from the Aithre Illyrian to allow for SPO2 blood oxygen levels to be provided to your avionics along with carbon monoxide data.
- OUTPUT TO AVIONICS: Simple installation using just one wire carrying the Aithre RS-232 data protocol.
- iOS: Integrated with the Aithre Connect iOS app to provide discrete and trend CO levels, plus Siri voice notifications to your paired headset (when paired to your iOS device), including 2 ppm, 10 ppm, 50 ppm, and a custom level.
- CSV FILES: CO trip history plotted against speed, altitude, and temperature is provided for your last three trips in the app and automatically saved after each trip as a CSV file to the iOS FILES app.
- SENSITIVE AND PRECISION CALIBRATED: Under 30 second CO sensor response between 0 – 255 ppm with 1 ppm resolution.
- COMPACT: Measures just 1.97” x 1.97” x 0.67” tall and weighs 1.1 ounces (mounting flange adds 0.75″ to base width).
- TEMPERATURE INDEPENDENT: Internal temperature adjustment circuit that compensates for temperature induced CO reading errors in the CO sensor between -10°C to +50°C.
- NO RECALIBRATION: State-of-the-art CO sensor requires no recalibration for 10 years under normal operating conditions.
- PRESSURE & ALTITUDE INDEPENDENT: The CO detector is not affected by pressure and altitude changes.
- HAND-CALIBRATED: Every Aithre CO detector is individually calibrated using high precision calibration CO gas and comes with a signed certificate of calibration.
| Weight | 0.1 lbs |
|---|---|
| Dimensions | 0.1 × 0.1 × 0.1 in |
| Brand | AITHRE |
SHIPPING INFORMATION
We can ship by UPS, or USPS and DHL Express. We ship nationally, and internationally.
Carriers In Use
SHIPPING COSTS
- International Shipping Quote has to be done manually due to dimensions, weight, end destination, and more. Please E-Mail us.
- Any manner or method is available, call if you need Priority 1-2 day or overnight shipping.
- We are shipping with UPS or USPS and DHL Express
Related products
AVI128EX 6-Place Smart O2 Valve with 925L Bottle and Altus Meso
AVI64EX 4-Place Smart O2 Valve with 925L Bottle and Altus Meso and Healthview
The Altus AVI64EX and 925L Aithre carbon fiber bottle is the first experimental installed smart oxygen system that is integrated
152L Bottle with Adjustable Constant Flow Regulator and Altus Meso
47L Bottle with Fixed Flow Regulator
The Aithre personal oxygen bottle is constructed from lightweight composite carbon fiber with an aluminum lining and is designed for
Shield eDot 5.0 CO Detector – FAA Part 23 Approved – Panel LED indicator – w/ iOS App
Mountain High Transfilling Hose for Aithre Fixed Flow Bottles
Aithre Boom Cannula and Adaptor
Now Available: Right Side Adaptor! Oxygen requires use if one is to realize its benefits, but the delivery mechanisms have
