RG28B DC–DC Power Converter | 28 VDC to Regulated 19 VDC, 14.7A
The RG28B power converter converts a 28 VDC input to a regulated 19 VDC output voltage. This converter is capable of delivering 280 continuous watts at 14 VDC (20A output). The 14 VDC output is buck converted from the input voltage; and therefore, the output voltage is not isolated from the input. A state of art “synchronous current mode switching” topology with surface mount technology facilitates the power conversion process. Control circuit with a synchronous PWM controller provides for voltage regulation and current limit. Circuit protection includes an output short circuit current limit and shuts down when the voltage feedback loop is opened.
Call for Pricing
Contact Cost Aero at 855-500-3044 for pricing
The RG28B power converter converts a 28 VDC input to a regulated 19 VDC output voltage. This converter is capable of delivering 280 continuous watts at 14 VDC (20A output). The 14 VDC output is buck converted from the input voltage; and therefore, the output voltage is not isolated from the input. A state of art “synchronous current mode switching” topology with surface mount technology facilitates the power conversion process. Control circuit with a synchronous PWM controller provides for voltage regulation and current limit. Circuit protection includes an output short circuit current limit and shuts down when the voltage feedback loop is opened.
Features
- Converts 28 VDC input to regulated 19 VDC output
- Delivers 280 continuous watts at 14 VDC
- Convection cooled via thermal conductor plate
- Power conversion uses “synchronous mode switching” topography with surface mount technology
- Provides circuit overload protection and short circuit protection
Specifications
Weight:
1.2 lb
Dimensions:
2.75 x 6.875 x 2.24 in
Input Voltage:
28 VDC — 32 VDC, nominal
Input Current:
10.8 Amps @ 28 VDC, full load
0.3 Amps @ no load, no load
Output Voltage:
14 VDC, regulated
Output Current:
0 — 20 amps, continuous
Power Output:
280 watts, continuous
420 watts, for 5 min. (min.)
Regulation:
1% for line
1% for load
1% for temperature
Overload:
delivers 110% output power for 2 hours minimum
Overload Protection:
Withstands without damage or degradation loads exceeding 110% to an output short circuit. Unit delivers rated output power upon removal of the overload condition
Short Circuit Protection:
Under a output short circuit condition, the current is limited to approximately 37.5 Amps
Efficiency:
92%, typical
Temperature:
-55°C to 71°C
Cooling:
Convection and thermal conduction through the bottom plate (No internal fan)
Altitude:
55,000 ft
Compliance:
FAA TSO C71
Environmental:
DO-160D/C by test, design similarity and/or design analysis per:
F2-BBB[STX]EWXDFSABAZZXLXXXX
Finish:
gold iridite per MIL-C-5541 class 1A
Weight | .1 lbs |
---|---|
Dimensions | 10 × 8 × 6 in |
Brand |
KGS Electronics |
You must be logged in to post a review.

SHIPPING INFORMATION
We can ship by UPS, or USPS and DHL Express. We ship nationally, and internationally.
Carriers In Use

SHIPPING COSTS
- International Shipping Quote has to be done manually due to dimensions, weight, end destination, and more. Please E-Mail us.
- Any manner or method is available, call if you need Priority 1-2 day or overnight shipping.
- We are shipping with UPS or USPS and DHL Express
Reviews
There are no reviews yet.