MaxPulse Landing Light Dual Control Unit | 12-28V, 10A, Spade Terminals
$420.00
The MaxPulse landing light controller is a solid state, compact and lightweight lighting controller. It features dual channels and provides Wig Wag and multiple rate control for any combination of LED, incandescent, and HID landing lights. The MaxPulse has an eight position function mode switch.
This MaxPulse landing light control unit has spade terminals and a 10A max current rating.
Features
- MaxPulse Landing Light Controller with spade or ring terminals
- Greatly increases the visibility of the aircraft in both daylight and nighttime operations which improves the safety of the flight
- Compact, lightweight, powerful, solid state reliability to give that Wig-Wag effect
- No outboard heat sinks or rheostats
- Works with all major brands of lights
- Gives the operator complete control over his landing light and/or taxi light
- Many settings to choose from
- X – both circuits are off
- S – Starboard/Right on only
- P – Port/Left on only
- S+P – Both circuits on
- A44 – Alternate at 44 PPM (STD)
- B44 – Both flash at 44 PPM
- A88 – Alternate at 88 PPM
- A120 – Alternate at 120 PPM
- FAA STC/PMA approved, with extensive AML
- RTCA/DO-160E Qualified
- Comes with MaxPulse unit, installation instructions, spade or ring terminals, placard, drill guide, and knob
Specifications
Weight:
1 oz
Dimensions:
Panel label: 1.6 x 1.6 in
Control unit: 1.27 in, diameter
Voltage range:
12 VDC to 28 VDC
Max current:
10 A
Operating temperature:
-30°C to 85°C
Internal Temperature Protection:
85°C
Storage Temperature:
-40 to 100°C
Maximum Internal Temperature:
+25°C at 10 A
| Weight | 0.1 lbs |
|---|---|
| Dimensions | 0.1 × 0.1 × 0.1 in |
| Brand | Seaton Engineering |
You must be logged in to post a review.
SHIPPING INFORMATION
We can ship by UPS, or USPS and DHL Express. We ship nationally, and internationally.
Carriers In Use
SHIPPING COSTS
- International Shipping Quote has to be done manually due to dimensions, weight, end destination, and more. Please E-Mail us.
- Any manner or method is available, call if you need Priority 1-2 day or overnight shipping.
- We are shipping with UPS or USPS and DHL Express
Related products
A200-PSO Oil Pressure Sensor
The A200-PSO is a bulk micro-machined, gage type pressure sensor for use in both harsh and benign media with superior accuracy over an operating temperature of -40°C to 105°C. It has superb accuracy of +/- 0.5% full scale.
It contains a custom ASIC which provides signal conditioning for calibration and temperature compensation at the point of measurement. Each sensor is traceable to NIST calibration standards.
Power requirements are 5V / 10mA. Signal output is linear and varies from 0.5V (0 PSI) to 4.5V (200 PSI). Overpressure burst rating is 600 PSI.
The sensor has a 1/8" NPT threaded port for connection to the oil pressure line.
Supplied with a 36" color coded cable.
When installed in accordance with the approved instructions and as part of a qualified instrument system, this pressure sensor is STC'd as a primary replacement.
P-300C: Capacitive Fuel Level Probe
A200-PSF Fuel Pressure Sensor
The A200-PSF is a bulk micro-machined, gage type pressure sensor for use in both harsh and benign media with superior accuracy over an operating temperature of -40°C to 105°C. It has superb accuracy of +/- 0.5% full scale.
It contains a custom ASIC which provides signal conditioning for calibration and temperature compensation at the point of measurement. Each sensor is traceable to NIST calibration standards.
Power requirements are 5V / 10mA. Signal output is linear and varies from 0.5V (0 PSI) to 4.5V (100 PSI). Overpressure burst rating is 300 PSI.
The sensor has a 1/8" NPT threaded port for connection to the fuel pressure line.
Supplied with a 36" color coded cable.
When installed in accordance with the approved instructions and as part of a qualified instrument system, this pressure sensor is STC'd as a primary replacement.
A200-TSA Outside Air Temperature Sensor
The A200-TSA is a monolithic temperature sensor with on-chip signal conditioning and an operating temperature of -50°C to 150°C. It has an accuracy of +/- 0.5°C over the full operating range.
The output voltage is proportional to the temperature x the supply voltage (ratiometric). The output swings from 0.25 V at −50°C to +4.75 V at +150°C using a single +5.0 V supply.
The temperature transfer function is:
VOUT = (V+/5 V) × [1.375 V +(22.5 mV/°C) × TA]
Power requirements are 5V / 1mA.
The sensor has a 5/16-24 threaded body and is supplied with two nylon mounting washers and a Nyloc fastening nut.
Supplied with a 48" color coded cable.
When installed in accordance with the approved instructions and as part of a qualified instrument system, this temperature sensor is STC'd as a primary replacement.
A200-TSO Oil Temperature Sensor
The A200-TSO is a monolithic temperature sensor with on-chip signal conditioning and an operating temperature of -50°C to 150°C. It has an accuracy of +/- 0.5°C over the full operating range.
The output voltage is proportional to the temperature x the supply voltage (ratiometric). The output swings from 0.25 V at −50°C to +4.75 V at +150°C using a single +5.0 V supply.
The temperature transfer function is:
VOUT = (V+/5 V) × [1.375 V +(22.5 mV/°C) × TA]
Power requirements (when used with any 200 Series instrument) are 5V / 1mA.
The sensor has a 5/8-18 threaded body and includes a copper crush washer.
Supplied with a 48" color coded cable.
When installed in accordance with the approved instructions and as part of a qualified instrument system, this temperature sensor is STC'd as a primary replacement.
A200-HAS Hall Effect Current Shunt
The A200-HAS is an economical and precise solution for DC current measurement in electrical systems up to +/- 100A in capacity.
The output of the device has a positive slope (Vcc / 2) when an increasing current flows through the primary copper conduction path. The internal resistance of this conductive path is 130 µΩ typical, providing low power loss.
The thickness of the copper conductor allows survival of the device at up to 5× overcurrent conditions. The terminals of the conductive path are electrically isolated from the sensor leads and provide a minimum isolation of 3,000V.
Current sense response time is 3uS.
Power requirements are 3V @ 10mA. Signal output is linear and varies from 0.0V (-100A) to 3.0V (+100). Zero current is represented by 1.5V.
The sensor has two 1/4" terminal posts for connection to the power bus.
Supplied with a 48" color coded cable.
When installed in accordance with the approved instructions and as part of a qualified instrument system, this current sense shunt is STC'd as a primary replacement.
Instrument Intensity Potentiometer – Rev 02
Instrument Intensity Potentiometer - Rev 2 - 5 Instruments ONLY
NOTE: This item is only required for use on products purchased on or AFTER 03-JAN-2013.
This potentiometer will support up to ten instruments in a single installation. It provides infinitely variable, uniform intensity control for all instruments.
These units are TSO qualified with all 200 Series instruments and is STC'd as a primary replacement instrument component under all flight conditions (day/night VFR and IFR).

Reviews