Showing 265–276 of 561 resultsSorted by price: high to low

PT-30GA – Pressure Transducer

$248.00

PT-30GA – Pressure Transducer FAA Approved Instrument FAA TSO’d, STC’d, PMA’d Accurate and stable, precise pressure measurements. Robust Construction, stainless

PT-100GA – Pressure Transducer

$248.00

PT-100GA – Pressure Transducer FAA Approved Instrument FAA TSO’d, STC’d, PMA’d Accurate and stable, precise pressure measurements. Robust Construction, stainless

Cockpit Cradle Kit

$245.00

This cockpit cradle allows the EKP V to be mounted directly to the panel. The docking station mechanically hosts the EKP V for ease of access in aircraft that does not need external device integration. Provides aircraft power supply and USB antenna.

Cable ACD-57 to TRIG devices (10ft)

$242.00

Interface cable to connect TRIG TT or TY units to an ACD-57. Includes interface converter circuitry. Connects up to two TRIG devices at once.

Features

  • D-SUB 15HD Connector and backshell for ACD-57, preconfigured.
  • Open ends on the TRIG unit's side.
  • Includes interface converter circuitry.

Compatible with: ACD-57, TRIG TT and TY series (TMAP Protocol, ACD-57 replaces TRIG control units)

Analog Temperature Probe | 11 ft, Series 301/303/307/655/803

$238.54

The analog probe provides temperature readings to digital outside/cabin air temperature gauges. The 11 ft length white cable allows the probe to be remotely installed.

7274-11 Series Circuit Breaker | 0.5 Amp Rating

$232.88

Klixon® 7274-11 series circuit breakers are small, lightweight, and low amperage devices specifically designed to protect aircraft and aerospace cables,

AOG FEE Aerospace Logic

$230.00

AOG FEE Aerospace Logic   For the fastest turn around time, choose an AOG FEE, and next day shipping on

A200-HAS Hall Effect Current Shunt

$227.70

The A200-HAS is an economical and precise solution for DC current measurement in electrical systems up to +/- 100A in capacity.

The output of the device has a positive slope (Vcc / 2) when an increasing current flows through the primary copper conduction path. The internal resistance of this conductive path is 130 µΩ typical, providing low power loss.

The thickness of the copper conductor allows survival of the device at up to 5× overcurrent conditions. The terminals of the conductive path are electrically isolated from the sensor leads and provide a minimum isolation of 3,000V.

Current sense response time is 3uS.

Power requirements are 3V @ 10mA. Signal output is linear and varies from 0.0V (-100A) to 3.0V (+100). Zero current is represented by 1.5V.

The sensor has two 1/4" terminal posts for connection to the power bus.

Supplied with a 48" color coded cable.

When installed in accordance with the approved instructions and as part of a qualified instrument system, this current sense shunt is STC'd as a primary replacement.

MARC-70 Install Kit | D Sub Connector

$226.00

The 305061-00 is a 50 socket D Sub connector for use with installation of MARC-70 interface modules.

Cable ACD-57 to Becker Radios (3ft)

$222.00

Interface cable to connect a Becker AR/RT-6201 VHF Radio to an ACD-57. Includes interface converter circuitry

Features

  • D-SUB 15HD Connector and backshell for ACD-57, preconfigured.
  • D-SUB 25 connector on the Becker side.
  • Includes interface converter circuitry.

Compatible with: ACD-57 Becker AR-6201, Becker RT-6201